Title

Automated Hydrolysis and Sample Preparation for the Analysis of 12 Opiates in Urine using the Thomson eXtreme Filter Vials® by LC-MS/MS

Description

This improved sample preparation method allows for the quantitative measurement of Opioids in urine. Opioids are highly addictive and affects nearly 5 million people in the U.S. Opioids include naturally occurring Opiates, semi-synthetic opioids derived from morphine and synthetic opioids. are analgesic alkaloids found naturally in Papaver somnife...

Product Used

Related Products

nano|Filter Vial® - PVDF 0.2µm

nano|Filter Vial® - PVDF 0.2µm

Pre-Slit Septum, Red Screw Cap

pn#25531-200

Standard|Filter Vial - PVDF 0.2µm

Standard|Filter Vial - PVDF 0.2µm

Pre-Slit Septum, Red Snap Cap

pn#35531-200

Multi-Use Press

Multi-Use Press

48 Position for Autosampler Ready Filter Vials

pn#35015

Toggle Press

Toggle Press

5 Position for Autosampler Ready Filter Vials

pn#35005

Automated Hydrolysis and Sample Preparation for the Analysis of 12 Opiates in Urine using the Thomson eXtreme Filter Vials® by LC-MS/MS

Poster presented at MSACL 2017
Nadine Koenig1, Crystal Xander1, Melanie Stauffer1, Dean Fritch2, Lisa Wanders3, Dennis Peterson3, Sam Ellis3
1 Health Network Laboratories, 794 Roble Road, Allentown, PA 18109
2 Analytical Associates, 225 Millwood Drive, East Greenville, PA
3Thomson Instrument Company, 1121 South Cleveland Street Oceanside, CA 92054

This improved sample preparation method allows for the quantitative measurement of Opioids in urine. Opioids are highly addictive and affects nearly 5 million people in the U.S. Opioids include naturally occurring Opiates, semi-synthetic opioids derived from morphine and synthetic opioids. are analgesic alkaloids found naturally in Papaver somniferum, poppy plant. The use of hydrolysis in the analysis of natural and synthetic opiates in urine has become standard practice in forensic toxicology. Many laboratories currently use solid phase extraction or solid liquid extraction techniques in the sample preparation of urine for the analysis for opiates. This improved automated sample preparation method evaluates the robustness for the quantitative measurement of opiates in urine without the need for SPE/SLE thereby reducing pipetting errors. The sample preparation of incurred urine, controls, standards and internal standard additions as well as the hydrolysis step are performed by a liquid handler. The Thomson eXtreme Filter Vials provide a simple and efficient extraction technique that has demonstrated adequate analyte recovery, reduced matrix interferences and the reduction of solvent and consumable waste.

Loading PDF…
Page 1 of

Related Application Notes

Automated Hydrolysis and Sample Preparation for the Analysis of 12 Opiates in Urine using the Thomson eXtreme Filter Vials® by LC-MS/MS

This improved sample preparation method allows for the quantitative measurement of Opioids in urine. Opioids are highly...

See Application Note

Sample Preparation for the Analysis of 12 Opiates in Urine using the Thomson eXtreme Filter Vials® by LCMS/MS

This improved sample preparation method allows for the quantitative measurement of Opioids in urine. ... samples are hy...

See Application Note

eXtreme Filter Vial Extraction for the Detection of Fentanyl & Analogues in Oral Fluid Samples

Use of oral fluid (saliva) in toxicology has been increasing within recent years due to its non-invasive, low cost effe...

See Application Note

Improved Sample Preparation Methods for Athlete Doping Analysis of Common Compounds in Urine by LCMS

The Australian Sports Drug Testing Laboratory, ... invested time in determining a limited number of comprehensive scree...

See Application Note

Improved Method for the Analysis of a Pain Management Supplemental Panel in Urine using the Thomson eXtreme|FV® by LC-MS/MS

Traditionally, SPE, SLE and centrifugation have been used to reduce matrix interference prior to MS analysis. ... eXt...

See Application Note